New energy battery motor chiller
Product Description
New energy battery motor chiller for the power battery charging management, the precision temperature control device for testing the permanent magnet synchronous motor, the switched reluctance motor, the asynchronous motor and its controller can realize the local + remote control mode through the liquid crystal controller panel;
With automatic fault protection function, it can output corresponding signals to ensure the safety of equipment. The main parts are all international brands, quality assurance, high-pressure electrostatic spray treatment on the surface, and auxiliary equipment can be added according to specific needs.
New energy battery motor chiller for the power battery charging management, the precision temperature control device for testing the permanent magnet synchronous motor, the switched reluctance motor, the asynchronous motor and its controller can realize the local + remote control mode through the liquid crystal controller panel;
With automatic fault protection function, it can output corresponding signals to ensure the safety of equipment. The main parts are all international brands, quality assurance, high-pressure electrostatic spray treatment on the surface, and auxiliary equipment can be added according to specific needs.
Features
- New energy battery motor chiller are widely used in extreme performance testing of motors and battery packs, rapid rise and fall thermal shock tests, and comprehensive environmental adaptability evaluation tests.
- The product is suitable for a new generation of energy-type battery packs, which can effectively test the super environmental adaptability of the battery pack, improve the safety and reliability of the vehicle, and ensure the good operation of the vehicle in a variety of complex environments.
- The temperature change range is usually from -40 to 100 degrees (expandable to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure; it is equipped with a powerful circulating pump to ensure the delivery of high-viscosity liquids;
- The test object is connected to a test platform adapter; the inside of the component is cooled and heated by the glycol aqueous solution; the test component needs to go through a specific temperature change curve and record the temperature change.
WE APPLY THE CONTROLLER DEVELOPED BY SANWOOD
parameter
Model | SM-475/2S | SM-4A15W/2S | SM-4A25W/2S | SM-4A38W/2S | SM-4A60W/2S | |
SM-475W/2S | ||||||
Temp Range | -40℃~+100℃ | |||||
Temperature control precision | ±0.5℃ | |||||
Temperature feedback | Pt100 | |||||
Temperature display | 0.01k | |||||
Flow control/Group | 1~20 L/min | 1~20 L/min | 1~20 L/min | 1~40 L/min | 1~40 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 2 groups | 2 groups | 2 groups | 2 groups | 2 groups | |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow description | When the temperature control is lower than -30℃, the flow rate is controlled within 80% of the maximum value. | |||||
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) | |||||
Heating Power | 7.5kW | 10kW | 15kW | 25kW | 38kW | |
Cooling | 100℃ | 10kW | 15kW | 25kW | 38kW | 60kW |
capacity | 20℃ | 10kW | 15kW | 25kW | 38kW | 60kW |
0℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
-20℃ | 6kW | 8.5kW | 14kW | 22kW | 35kW | |
-35℃ | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Compression | Emerson Valley Wheel Compressor | |||||
Expansion valve/solenoid valve | Danfoss Thermal Expansion Valve / Emerson Solenoid Valve | |||||
Oil distributor | Emerson | |||||
Dry filter, Pressure control | Danfoss | |||||
Evaporator | Danfoss/KAORI plate heat exchanger | |||||
Circulating pump | German brand magnetic drive pump | |||||
Frequency converter | Delta | |||||
Flow,Pressure sensor | Electromagnetic flowmeter, Johnson Controls pressure sensor | |||||
Input, Display | 10 inch color touch screen \ Siemens S7-1200 PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||||
Closed circulation system |
The whole system is a fully closed system, there will be no oil mist at high temperature, low temperature does not absorb water in the air, the system in operation will not because of high temperature pressure rise, low temperature automatically add heat conduction medium. | |||||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||||
Connection size | There are two groups of inlet and outlet, G3/4 | |||||
Cooling water@20℃ | 1800L/H | 2800L/H | 4500L/H | 7000L/H | 12000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||||
Condenser(A) | Optional air-cooled type, upper air outlet, the equipment size will be increased. | |||||
Power 380V50HZ | 16.5kW | 24kW max | 36kW max | 56kW max | 81kW max | |
Dimension cm | 70*100*175 | 80*120*185 | 100*150*185 | 120*180*205 | 145*205*225 | |
Weight(W) | 360KG | 450kg | 750kg | 1000kg | 1700kg | |
Optional | 220V 60HZ Three phase 400V 50HZ Three phase 440V 60HZ Three phase | |||||
Optional | Extend to -40~+135℃ | |||||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. | |||||