Walk-in Battery And Altitude Test Chamber
The walk in altitude test chamber allows the user to control the temperature of the test room, and at the same time allows the tested product to withstand various altitudes, up to 100,000 feet, and the optional altitude range extends to 150,000 feet.
The combination of these elements can accurately simulate the actual conditions that the product may encounter at different heights.
Test standards
Meets international test standards DO160, ASTM, MIL-STD-781/-810.
The combination of these elements can accurately simulate the actual conditions that the product may encounter at different heights.
Test standards
Meets international test standards DO160, ASTM, MIL-STD-781/-810.
Features
- The built-in self-diagnostic function can continuously monitor the operating system, track problems before they occur and reduce troubleshooting time.
- The access port can be used to easily enter the environmental room to adjust the product under test.
- Almost all SANWOOD chambers have a standard window. Other windows are available. Users can also customize the size to suit product browsing.
- For equipment going to Canada or the European Union, SANWOOD can manufacture equipment in accordance with CSA or CE electrical regulations to ensure the safety of equipment users and facilities.
Refrigeration System
- The humidification system pipeline is separated from the power supply, the controller, and the circuit board to avoid the leakage of water from the pipeline and affect the circuit, thereby improving safety.
- Compressors equipped with world famous brand such as Tecumseh (France made), Bitzer or GEA BOCK (Germany made).
- It applies Denmark DANFOSS and Japanese SAGLNOMIYA solenoid valves to improve the overall reliability of the equipment.
- Unit module standardization:Convenient installation, commissioning and subsequent maintenance are more convenient and cost-effective.
Electrical System
- The overall layout of the circuit cabinet looks very neat and professional. Our circuits are arranged in accordance with UK standards and are equipped with complete circuit diagrams. Each line has a unique code which is clearly defined and easy to locate for troubleshooting.
- We use electrical components of world famous brands, such as Schneider from France,Carlo Gavazzi from Switzerland,Mitsubishi from Japan,Rainbow from Korea.
WE APPLY THE CONTROLLER DEVELOPED BY SANWOOD
parameter
Model | SM-VTH-250-CC | SM-VTH-500-CC | SM-VTH-1000-CC | SM-VTH-2000-CC | |
Temperature | Temperature control range | -70℃~180℃ (A:0℃~180℃;B:-20℃~180℃;C:-40℃~180℃;D:-70℃~180℃) | |||
Temperature fluctuation | ±0.5℃ | ||||
Cooling rate | 180.0℃~-70.0℃ Within 120mins (1.0~2.0℃/min) | ||||
Heating rate | -70.0℃~180.0℃ Within 100mins (2.0~3.0℃/min) | ||||
Temperature uniformity | ±1.5℃ (-40.0℃~100.0℃) | ||||
±2.0℃ (100.1℃~180.0℃or-40.0℃~-70.0℃) | |||||
Pressure | Pressure range | Normal pressure~0.5kpa(500pa) | |||
Pressure error | ±2kpa(>40kpa),±5%(2kpa~40kpa),±0.1kpa(<2kpa) | ||||
Depressurization time | Normal pressure~1kpa,about 30 mins; | ||||
Pressure recovery time | <10kpa/min | ||||
Humidity | Humidity control range | 20.0%RH~98.0%RH(work under atmospheric humidity) | |||
Humidity fluctuation | ±2.0% RH | ||||
Humidity uniformity | ±5.0%RH | ||||
Material / components |
Internal material | Adopt 2mm thickness stainless steel plate (SUS304) | |||
External material | Adopt 10mm thickness cold rolled steel plate fully welded / powder sprayed | ||||
Heat insulating material | 100mm thickness polyurethane plate+10mm thickness mineral wool | ||||
Fan | Centrifugal blower | ||||
Compressor | France Tecumseh, Germany Bock, Germany Bitzer | ||||
Condenser | Air cooling, water cooling | ||||
Refrigerant | R404A、R23、R508 | ||||
Evaporator | Fin - and - Tube Heat Exchanger | ||||
Heater | Nickel chromium alloy heating wire | ||||
Humidifier | Steam humidifier | ||||
Size | Inner size(mm)W*H*D | 550*600*700 | 700*800*900 | 1000*1000*1000 | 1400*1200*1200 |
Outer size(mm)W*H*D | 2000*1060*1900 | 2500*1260*2050 | 2720*1460*2130 | 3150*1650*2050 | |
Volume(L) | 250L | 500L | 1000L | 2000L | |
Operating ambient temperature | +5 ~ 35℃ | ||||
Power supply | 380V AC 50/60Hz | ||||
Controller | SANWOOD SH5600:Equipped with RS232 port;(7.0 inch controller)USB data export |