Battery Safety Test
Test standards:
•IEC 62133-2017
Electrical System
- The overall layout of the circuit cabinet looks very neat and professional. Our circuits are arranged in accordance with UK standards and are equipped with complete circuit diagrams. Each line has a unique code which is clearly defined and easy to locate for troubleshooting.
- We use electrical components of world famous brands, such as Schneider from France,Carlo Gavazzi from Switzerland,Mitsubishi from Japan,Rainbow from Korea.
WE APPLY THE CONTROLLER DEVELOPED BY SANWOOD
parameter
Model | SM-8007 |
Temperature Range | -10℃ ~ +80℃ (controllable) |
Temperature Rising Rate | Ave.3℃/min(-10℃ to 80℃, nonlinear / no-load) |
Temperature Cooling Rate | Ave.1℃/min(80℃ to 10℃, nonlinear / no-load) |
Inner Chamber Dimension | W600 x H750 x D500mm |
External Chamber Dimension | W1170 x H1850 x D1020mm |
Inner Chamber Material | Stainless steel with mirror-finish, bottom reinforcement |
External Chamber Material | Cold-rolled steel with powder spraying |
Observation Window | The single-opening door is accompanied by a 3-layer vacuum large glass observation window (W430mm x H580mm); The door frame is equipped with electric heating (automatic adjustment) anti-frost, anti-condensation device,so that you can clearly observe the test status of the test sample in the cabinet through the observation window at any time. |
Max. Loading | 200KGS |
Resolution | 1/10,000 |
Force Accuracy | ≤ 0.5% |
Displacement resolution | 1/1,000 |
Accuracy of displacement | ≤0.5% |
Speed Range | 0.01- 5mm/s |
Effective Range | 0 ~ 200mm |
Max. Test Area | 300 x 300mm (can be customized) |
Voltage Range | 0- 60V |
Voltage Resolution | 5mV |
Voltage Acquisition Frequency | 100HZ |
Control System | Servo motor + servo control system |
Safety Protection | Explosion-proof pressure relief device, smoke exhaust device, fire extinguishing system, electronic door lock system, safety stop switch |