Battery Charge/Discharge Test
Battery high low temperature test chamber is designed to test all types of batteries, including lithium-ion batteries. The battery test chamber has many safety functions built into the test chamber, which can handle battery tests and prevent safety accidents.
Charge/discharge cycle testing, which determines the number of times a battery can be used by evaluating it until it deteriorates after repeated cycles of charging and discharging.
In the laboratories involved in battery testing, tests based on charge and discharge cycles are a key activity. The instruments used for this type of test usually perform harsh and lengthy test protocols on the battery and can usually be connected to various instruments.
Test standards
TIEC 62660-2,SAE J2464,IEC 60086-4,UL 1642,UN 38.3,IEC 61960,IEC 62133,UL 2054,
IEEE 1625,IEEE 1725
Charge/discharge cycle testing, which determines the number of times a battery can be used by evaluating it until it deteriorates after repeated cycles of charging and discharging.
In the laboratories involved in battery testing, tests based on charge and discharge cycles are a key activity. The instruments used for this type of test usually perform harsh and lengthy test protocols on the battery and can usually be connected to various instruments.
Test standards
TIEC 62660-2,SAE J2464,IEC 60086-4,UL 1642,UN 38.3,IEC 61960,IEC 62133,UL 2054,
IEEE 1625,IEEE 1725
Structural Features
- The inner chamber material is made of SUS#304 stainless steel with 1.2mm thickness. Full welding structure, its sealing is very well and it’s not easy to get cracked.
- The external material is made of cold-rolled plate with 1.5mm thickness, it has gone through brushing, polishing, painting treatment, it's not easy to get scratched.
- The insulation material is made of polyurethane foam with thickness of 100mm.
- The door seal adopts double silicon rubber sealing material.
- The observation window is 4 layers of tempered glass, the size you can choose by yourself.
- In addition, in order to prevent frosting on the observation window when running low temperature, we setup a heating wires inside to get it di-frosting.
- Both sides of chamber are equipped with a diameter 100mm cable port, the silicon plug is high & low temperature resistance.
- The door lock developed and designed by Sanwood with lever theory.
Refrigeration System
- Compressors equipped with world famous brand such as Tecumseh (France made), Bitzer or GEA BOCK (Germany made).
- Shock absorption and noise reduction process,slow down the vibration, protect the compressor.The new pipe bending technology: The bending process can minimize the connector point and make refrigerant flow more efficiently.
- It applies Denmark DANFOSS and Japanese SAGLNOMIYA solenoid valves to improve the overall reliability of the equipment.
- MP10 module has motor over-heating protection (with LED indicator), exhaust temperature over-heating protection (requires optional temperature monitoring probe and LED indicator), power indicator, alarm function.
Electrical System
- The overall layout of the circuit cabinet looks very neat and professional. Our circuits are arranged in accordance with UK standards and are equipped with complete circuit diagrams. Each line has a unique code which is clearly defined and easy to locate for troubleshooting.
- We use electrical components of world famous brands, such as Schneider from France,Carlo Gavazzi from Switzerland,Mitsubishi from Japan,Rainbow from Korea.
WE APPLY THE CONTROLLER DEVELOPED BY SANWOOD
parameter
Model | SMC-80-CC-FB | SMC-150-CC-FB | SMC-225-CC-FB | SMC-408-CC-FB | SMC-800-CC-FB | SMC-1000-CC-FB | SMC-1500-CC-FB | |
Temperature | Temperature control range |
-70℃~180℃ (A:0℃~180℃;B:-20℃~180℃;C:-40℃~180℃;D:-70℃~180℃) |
||||||
Temperature fluctuation | ±0.5℃ | |||||||
Cooling rate | 180.0℃~25.0℃ Cooling rate 2.0~3.0℃/min 25.0℃~-40.0℃ Cooling rate 1.0~2.0℃/min -40.0℃~-70.0℃ Cooling rate0.7~1.5℃/min |
|||||||
Heating rate | -70.0℃~180.0℃ Within 60 mins 3.0~5.0℃/min | |||||||
Temperature uniformity | ±1.5℃ (-40.0℃~100.0℃) | |||||||
±2.0℃ (100.1℃~180.0℃or-40.0℃~-70.0℃) | ||||||||
Humidity | Humidity control range | 20.0%RH~98.0%RH | ||||||
Humidity fluctuation | ±1.0% RH | |||||||
Humidity uniformity | ±2.0%RH | |||||||
Material / components |
Internal material | Adopts 1.2mm thickness stainess steel(SUS304) | ||||||
External material | Adopts 1.2mm thickness Cold rolled steel sheet / powder spraying | |||||||
Heat insulating material | 100mm thickness polyurethane plate+10mm thickness mineral wool | |||||||
Fan | Centrifugal blower | |||||||
Compressor | Semi-closed Germany Bock, Germany Bitzer | |||||||
Condenser | Air cooling, water cooling | |||||||
Refrigerant | R404A、R23、R508 | |||||||
Evaporator | Fin - and - Tube Heat Exchanger | |||||||
Heater | Nickel chromium alloy heating wire | |||||||
Humidifier | Steam humidifier | |||||||
Options | Standard configuration | 2 ∅100MM pressure relief port, 4 explosion-prood chains | ||||||
Multipoint temperature monitor |
Adopts Sanwood developed controller, which can be used to acquire surface temperature points of multiple products | |||||||
C02 fire extinguisher | Automatic fire extinguishing and automatic shutdown of the machine to protect the equipment from burning | |||||||
C0, H2 gas detector | When the battery will produce gas, it will detect gas solubility and discharge to outdoor when it exceeds the standard | |||||||
Exhaust valve | When the test sample produces harmful gas, ventilate and exhaust internally | |||||||
Size | Interior size(mm) W*H*D |
400*500*400 | 500*600*500 | 600*750*500 | 800*850*600 | 1000*1000*800 | 1000*1000*1000 | 1200*1000*1250 |
Outer size(mm) W*H*D |
600*1590*1160 | 700*1665*1275 | 800*1870*1315 | 1000*1950*1410 | 1200*2085*1590 | 1200*2085*1790 | 1400*2100*2030 | |
Volume(m³) | 80L | 150L | 225L | 408L | 800L | 1000L | 1500L |
Product Catalog:
Battery test solution
Battery High Low Temperature Test Chamber | Battery Test Chamber | SANWOOD Environmental Chambers